TickSig
Indicator guide

Mike support/resistance

Derives support/resistance reference levels from recent prices.

Purpose and construction

Derives support/resistance reference levels from recent prices.

Mike support/resistance is applied to the chart series using the local definition below. Each period counts one bar on the active chart. The same period therefore covers a different amount of time on daily and intraday charts.

How to read it

Treat levels as rolling references and check actual price reactions.

Confirm the inputs and settings before comparing the indicator with price. On an open bar, close, extremes and volume can still change, so the reading can update before the bar closes.

Parameters

ParameterDefault
N10

Parameter names match the variables in the calculation. After changing a lookback or smoothing period, recalculate on the same data to compare response speed. Defaults from another platform may not match this definition.

Actual application chart

This screenshot shows Mike support/resistance running on the application's TSLA daily chart. Price and indicator share the same market history, preserving the curves, bars and markers drawn by the application.

Actual application screenshot of Mike support/resistance on the TSLA daily chart
Captured 2026-10-19; market data through 2026-10-16. Only surrounding interface elements were cropped; the indicator was not redrawn.

Treat levels as rolling references and check actual price reactions.

  1. Check the displayed indicator name and parameters against the version currently loaded.
  2. Align price and indicator by time, then compare direction, turning points and marker locations.
  3. After changing settings or timeframe, wait for calculation to finish before saving the same interval for comparison.

The screenshot records a historical chart display, not executed orders, returns or a win rate.

Local calculation

The local definition is shown below. Display labels can be translated; the case calculation uses original source identifiers. A shared indicator name does not guarantee identical calculations across platforms.

HLC:=REF(MA((HIGH+LOW+CLOSE)/3,N),1);
HV:=EMA(HHV(HIGH,N),3);
LV:=EMA(LLV(LOW,N),3);
STOR:EMA(2*HV-LV,3);
MIDR:EMA(HLC+HV-LV,3);
WEKR:EMA(HLC*2-LV,3);
WEKS:EMA(HLC*2-HV,3);
MIDS:EMA(HLC-HV+LV,3);
STOS:EMA(2*LV-HV,3);

Limitations

  • Treat levels as rolling references and check actual price reactions.
  • Timeframe, adjustments, warm-up length and data units affect results. Align these before comparing charts.

Questions

Why can Mike support/resistance differ across platforms?

Compare inputs, default periods, smoothing, offsets and data units before comparing the final value. This guide uses the local source definition rather than assuming that an external example has the same settings.

Does the example show a real trade?

No. Figures show the indicator running on historical market data in the application. They contain no executed orders and make no return or win-rate claim.

References

The calculation comes from the project’s indicator registry. Primary references below provide related conceptual reading. Figures are captured from the running application.